China-CCC-Certification

:

CCC-Laws

-

CCC Certification Guide for Electrical Wires and Cables Product

CCC mark,CCC certification,china ccc certification application,ccc china compulsory certification applying
CCC mark,CCC certification,china ccc certification application,ccc china compulsory certification applying
Make CCC As HomepageMake CCC As Homepage
Add Current Page To FavoriteAdd Current Page To Favorite
The first global professional service organization of CCC China Compulsory CertificationContact Us

CCC Certification Guide for Electrical Wires and Cables Product

CCC Certification Guide for Electrical Wires and Cables Product

To help you know the requirement of CCC application, then facilitate the certification schedule, avoiding application letter filling mistake and unnecessary reworking, please read this guide carefully before you fill in the application. The following <Electrical Wires and cables product unit division and related information list> (hereafter referred to table 1 as simply) will be your reference to provide important information for filling CCC certification application.

1.Usual procedure of certification

The usual procedure of CCC certification: certification application + type test + factory inspection. You should confirm product type and executive standard. All product listed in executive table 1 are needed to carry out CCC certification.

2. Certification application

You should pay great attention to the following when you apply on line through website:

(1) Filling in application depending unit, each unit has its application letter;

(2) The filling of 'applicant name', 'manufacturer name' and 'factory name' in the application letter should conformity with unit register name of business license.

(3) The filling of 'applicant address' and 'manufacturer address' in the application letter should conformity with register address of business license, the filling of 'factory address' should conformity with the actual address of production site, all the address information should include in name of province and municipality.

(4) 'Product name' in Chinese and in English in application letter should be filled in accord with table 1.

(5) 'Model and specification' should be filled in accord with product standard, model and specification usually include in 4 parts, namely model, rated voltage, nominal cross section and insulating core quantity, 'model' and 'rated voltage' are relative regular what can be filled in accord to the corresponding part in table 1; 'nominal cross section' and 'insulating core quantity' should be filled in accord to enterprise actual production capacity( table 1 has given you the stipulated range of product standard for reference); filling examples:

60227 IEC 01(BV) 450/750V 1.5-95 (1 core);

60227 IEC 01(BV) 450/750V 1.5-95 (1 core);

60227 IEC 53(RVV) 300/500V 0.75-2.5 (2-3 cores);

60227 IEC 53(RVV) 300/500V 0.75-2.5 (2-3 cores);

(6) All wires and cables that execute gb5023-2008 standard have color requirement, please indicate requested color on postposition of product specification if you only apply for one color on wires and cables, otherwise we will consider that you apply for all colors on wires and cables, the external surface color of submitted sample should include in black and white.

(7) Some models of wires and cables have both circular and flat (E.g. 60227 IEC 53(RVV) 2×0.75) ,then you should also indicate requested color on postposition of specification, otherwise the submitted sample should include in circular and flat.

(8) 'Product safety standard' in application letter should be filled in accord to 'standard' in table 1.

(9)'Trade mark' in application letter should be filled in registered trademark( has acquired registered trademark already);

3. After submitting the application

You should login our website frequently to look over certification schedule after submitting application letter. If the application has been accepted and attended, please submit writing documents accord to documents list, and preparing sample accord to sample submitting notice and send to designated inspection institute.

4. Submitting sample and type test

We choose sample accord to certification implementation rules, generally speaking, the chosen sample should cover all kinds of models in one unit, maximum and minimum cross section, maximum and minimum core quantity, circular and flat (if available), black and white (if you apply for certification for all colors). So, every enterprise should apply accord with their actual production capacity to avoiding frequent revision and prolonging certification time. In the region where the inspection station division has overlapping, you can note which inspection station you want to submit sample to in application letter remarks, we will consider and make balance by actual condition when issue submitting sample notice.

5. Factory inspection

After passing type test, we will inform you to carry out factory inspection.

6. Payment

We will send payment notice to you by website when we need your payment, please remit in time accord to the notice requirements, and attach the remit proof under receipt, noting information about invoiced unit name, unit address, post code , contact person, phone number and etc, then fax this receipt to us.

7. Any questions you meet in certification procedure, please contact us by phone or Phone number: 021-51095580-83, 021-51095580-85

Fax: 86-021-51095580-807

Electrical Wires and Cables Product Unit Division and Related Information List( table 1)

Item No.
Product Name(Chinese/English)
Model and Specification
Standard
(model, rated voltage)
(nominal cross section, insulating core quantity)
Unit 1
PVC insulated non-sheathed cables and wires
60227 IEC 01(BV) 450/750
1.5-400 (1 core);
GB5023.3-1997
60227 IEC 02(RV) 450/750
1.5-240 (1 core);
60227 IEC 05(BV) 300/500
0.5-1.0 (1 core);
60227 IEC 06(RV) 300/500
0.5-1.0 (1 core);
60227 IEC 07(BV-90) 300/500
0.5-2.5 (1 core);
60227 IEC 08(RV-90) 300/500
0.5-2.5 (1 core);
BV 300/500
0.75-1.0 (1 core);
JB8734.2-1998
BLV 450/750
2.5-400 (1 core);
BVR 450/750
2.5-70 (1 core);
Unit 2
PVC insulated and PVC sheathed cables
60227 IEC 10(BVV) 300/500
1.5-35 (2-5 core);
GB5023.4-1997
BVV 300/500
0.75-10 (1 core);
JB8734.2-1998
BLVV 300/500
2.5-10 (1 core);
BVVB 300/500
0.75-10 (2-3 cores);
BLVVB 300/500
2.5-10 (2-3 cores);
Unit 3
PVC insulated flexible cables and wires
60227 IEC 41(RTPVR);
---
GB5023.5-1997
60227 IEC 42(RVB) 300/300
0.5-0.75 (2 cores);
60227 IEC 43(SVR) 300/300
0.5-0.75 (1 core);
60227 IEC 52(RVV) 300/300
0.5-0.75 (2-3 cores);
60227 IEC 53(RVV) 300/500
0.75-2.5 (2-5 cores);
RVS 300/300
0.5-0.75 (2 cores);
JB8734.3-1998
Unit 4
PVC insulated and PVC sheathed elevator cables and/or oil-resistant flexible cables
60227 IEC 71f(TVVB) 300/500
0.75-1 (3-24 cores);
GB5023.6-1997
60227 IEC 71f(TVVB) 450/750
1.5-2.5 (3-12 cores), 4-25 (4-5 cores);
60227 IEC 74(RVVYP) 300/500
0.5-2.5 (2-60 cores);
GB5023.7-1997
60227 IEC 75(RVVY) 300/500
0.5-2.5 (2-60);
Unit 5
PVC insulated wire for installation and/or screened wires
AV 300/300
0.08-0.4 (1 core);
JB8734.4-1998
AV-90 300/300
0.08-0.4 (1 core);
AVR 300/300
0.08-0.4 (1 core);
AVR-90 300/300
0.08-0.4 (1 core);
AVRB 300/300
0.12-0.4 (2 cores);
AVRS 300/300
0.12-0.4 (2 cores);
AVVR 300/300
0.08-0.4 (2 cores),
0.12-0.4 (3-24 cores);
AVP 300/300
0.08-0.4 (1 core);
JB8734.5-1998
AVP-90 300/300
0.08-0.4 (1 core);
RVP 300/300
0.08-2.5 (1 core),
0.08-1.5 (2 cores);
RVP-90 300/300
0.08-2.5 (1 core),
0.08-1.5 (2 cores);
RVVP 300/300
0.08-2.5 (1 core),
0.08-1.5 (2 cores),
0.12-1.5 (3 cores),
0.12-0.4 (4-24 cores);
RVVP1 300/300
0.08-2.5 (1 core),
0.08-1.5 (2 cores),
0.12-1.5 (3 cores),
0.12-0.4 (4-24 cores);
Unit 6
Heat-resistant rubber insulated cables
245 IEC 03(YG) 300/500
0.5-16 (1 core);
GB5013.3-1997
245 IEC 04(YYY) 450/750
0.5-10 (1 core),
1.5-95 (2 cores),
0.5-95 (3 cores);
GB5013.7-1997
245 IEC 05(YRYY) 450/750
0.5-10 (1 core),
1.5-95 (2 cores),
0.5-95 (3 cores);
245 IEC 06(YYY) 300/500
0.5-1 (1-3 cores);
245 IEC 07(YRYY) 300/500
0.5-1 (1-3 cores);
Unit 7
Rubber insulated elevator cables and/or welding machine cables
245 IEC 70(YTB) 300/500
0.75-1 (6-30 cores);
GB5013.5-1997
245 IEC 74(YT) 300/500
0.75-1 (6-30 cores);
245 IEC 75(YTF) 300/500
0.75-1 (6-30 cores);
245 IEC 81(YH)
16-95;
GB5013.6-1997
245 IEC 82(YHF)
16-95;
Unit 8
rubber sheathed flexible cables and wires for general purposes
245 IEC 53(YZ) 300/500
0.75-2.5 (2-5 cores);
GB5013.4-1997
245 IEC 57(YZW) 300/500
0.75-2.5 (2-5 cores);
245 IEC 66(YCW) 450/750
1.5-400 (1 core),
1-25 (2 cores),
1-95 (3 cores),
1-150 (4 cores),
1-25 (5 cores);
245 IEC 58(YSF) 300/500
0.75-1.5 (1 core),
1.5 (2 cores);
245 IEC 58f(YSF) 300/500
0.75-1.5 (1 core),
1.5 (2 cores);
YQ 300/300
0.3-0.5 (2-3 cores);
JB8735.2-1998
YQW 300/300
0.3-0.5 (2-3 cores);
YZ 300/500
4-6 (2-5 cores),
0.75-6 (6 cores),
1.5-6 (3+1 cores);
YZW 300/500
4-6 (2-5 cores),
0.75-6 (6 cores),
1.5-6 (3+1 cores);
YZB 300/500
0.75-6 (2-6 cores);
YZWB 300/500
0.75-6 (2-6 cores);
YC 450/750
1.5-400 (1 core),
1.5-95 (2 cores),
1.5-150 (3-4 cores),
1.5-25 (5 cores),
2.5-150 (3+1 cores);
YCW 450/750
35-95 (2 cores),
120-150 (3 cores),
2.5-150 (3+1 cores);
Unit 9
Rubber insulated braided flexible cable
245IEC51(RX) 300/300
0.75-1.5 (2-3 cores);
GB5013.4-1997
RX 300/300
0.3-4 (2-3 cores);
JB8735.3-1998
RXS 300/300
0.3-4 (2 cores);
RXH 300/300
0.3-4 (2-3 cores);
Unit 10
Insulated cables(wires) for railway vehicles
DCXF series, DCH series, DCEH series
(note:temperature should be noted when temperature>70)
GB12528-1990
JB8145-1995
Unit 11
Flexible rubber-sheathed cable for coal-excavator
UC series, UCP series, UCJB series, UCPJR series, UCPT series
GB12972-1991
Unit 12
Movable flexible rubber-sheathed cables for mining purposes
UY series, UYP series, UYPJ series, UYPT series, UYPD series, UYPTD series, UYQ series
GB12972-1991
Unit 13
Electrical drill machine cables for mining purposes
UZ series, UZP series
GB12972-1991
Unit 14
Miner cap lamp cable
UM series, UM-1 series
GB12972-1991
(Note: Filling format of unit10—unit14 model and specification: model+ rated voltage+ nominal cross section (make note of power line core quantity only if mining purposes)+core quantity range)

Statement: this guide is only for your reference, you should comply with implementation rule or product standard first if the content of it is not correspond with <electrical wires and cables product certification implementation rules> or <product standard>, we are responsible for explain this guide.


The Process of CCC Certification For New Application(http://www.china-ccc-certification.com/170.html)
Guideline for CCC certification alternation application(http://www.china-ccc-certification.com/178.html)

Keywords Search


Tel 0086-21-51095580-805; Fax 0086-21-51095580-807; E-mail cccwto#163.com
Shanghai Compulsory Certification Information & Technology Co.,Ltd. © All Rights Reserved